The VS-626MR5 is a highly reliable AC vector controlled inverter drive designed for controlling high speed, compact AC motors used in machine tool spindle drive applications. Vector controlled technology through the use of a digital signal processor and proprietary algorithms for speed, torque, and current control allows for minimum speed and torque variations during cutting. This impacts accuracy and surface finish of precision parts. 100% back-to-line power regeneration provides quick spindle deceleration times not limited by the ohmic value of externally mounted regeneration resistors. This allows for faster tool changes and increased machine productivity.
Error codes
Error code : Overcurrent (Fault #01)
Meaning: Output current exceeded overcurrent detection level.
Corrective actions:
Check the wiring
Check the input supply voltage
Check the AC reactor
Check the load shaft (Inverter, Servo) capacity
Error code : Main circuit fuse blown (Fault #04)
Meaning: Main circuit fuse was blown.
Corrective actions: Check for damaged transistor, load short circuit, ground short, etc…
Error code : Overload (Fault #05)
Meaning: Output current exceeded overload level.
Corrective actions:
Reduce the load
Check the load shaft (Inverter, Servo) capacity
Error code : Output overvoltage (Fault #11)
Meaning: Output voltage exceeded overvoltage level.
Detection level:
200V class: Approx. 400V
400V class: Approx: 800V
Corrective actions:
Check the input supply voltage
Check the load shaft (Inverter, Servo) capacity
Error code : Main circuit undervoltage (Fault #12)
Meaning: Main circuit output voltage became lower than undervoltage detection level.
Corrective actions: Check the input supply voltage
Error code : Built-in MC operation fault (Fault #23)
Meaning: Magnetic contactor did not function
Corrective actions: Replace the unit
Error code :CPU built-in A/D error (Fault d2)
Meaning:Built-in A/D Converter error
Corrective actions: Replace the control PCB
Error code : ROM error (Fault F0)
Meaning: Memory (PROM) error
Corrective actions: Replace the control PCB
Error code: EEPROM error (Fault F1)
Meaning: Memory (EEPPROM) error
Corrective actions: Replace the control PCB
Error code : CPU error (Fault F5)
Meaning: CPU error
Corrective actions: Replace the control PCB