top of page

CIMR-VMS2018 Yaskawa

Cross references: CIMR-VMW2018 Voltage: 230V Serial: VS626-VM3 CANADA YASKAWA AUTHORIZED SERVICE CENTRE

Numéro de pièce du fabricant : 

123-456-789

Manufacturer part number : 

CIMR-VMS2018

Détails

CIMR-VMS2018 Yaskawa

 

30 KVA , Serial VS626-VM3

Varispeed-626VM3 drives (VS-626VM3) combine a compact, high speed AC spindle drive motor with a digital vector-controlled, high performance transistor inverter (controller) with regenerative function.

The VS-626VM3 Drives has highly reliable adjustable speed AC spindle motor drives for NC machine tools such as machining centers and lathes, and manufacturing facilities such as transfer machines and testers. They assure exceptional stability, even at high speeds under severe operating conditions.

The features of the VS-626VM3 are as follows:

  •          800 r/min max and constant power range (1:5.3) (for 7.5 kW or below)
  •          Constant power (1:12) with winding selection (No speed change gear required)
  •          Two series for power voltages of 200V and 400V
  •          Precise setup of position and speed by fully digitalized control
  •          Compact and lightweight

 


Error codes

 

 

 

 

Error code : F-000

Protective Function : Winding Selection Failure

Explanation : Windings were not selected within set time.

 

Error code: F-001

Protective Function: Emergency Stop Failure

Explanation: Operation was not stopped within 10 seconds after emergency stop was commanded.

 

Error code: F-100

Protective Function: Inverter Output Overcurrent

Explanation: Output current exceeded set overcurrent value.

 

Error code: F-200

Protective Function: Inverter Internal MC Operation Failure

Explanation: The magnetic contactor in the input block is not functioning.

 

Error code: F-201

Protective Function: MCCB Trip

Explanation: The MCCB in the input block tripped.

 

Error code: F-300

Protective Function: Inverter Input Overcurrent

Explanation: Input current exceeded set overcurrent value.

 

Error code: F-400

Protective Function: Inverter Overvoltage

Explanation: Inverter DC bus voltage exceeded set overvoltage value.

 

Error code: F-500

Protective Function: Motor Overspeed

Explanation: Motor speed exceeded 120% of max. set speed.

 

Error code: F-600

Protective Function: Power Voltage Error 1

Explanation: Synchronous power signal is lost (at power-ON).

 

Error code: F-601

Protective Function: Power Frequency Error 1

Explanation: Whether 50 Hz or 60 Hz cannot be determined (at power-ON).

 

Error code: F-602

Protective Function: Power Voltage Error 2

Explanation: Low-Voltage (85% or lower), momentary power loss (for 0.02 second or longer), or open phase.

 

 

Error code: F-603

Protective Function: Power Frequency Error 2

Explanation: Excess power frequency deviations (Deviation is 5% or the frequency or greater)

 

Error code: F-604

Protective Function: Power Voltage Error 3

Explanation: Low-Voltage of control power source (175 VAC or lower) or power loss.

 

Error code: F-700

Protective Function: Inverter Output Overload

Explanation: Output current of 120% of 30-minute rating flowed for one minute or longer.

 

Error code: F-701

Protective Function: Inverter Input Overloard

Explanation: Input current of 120% or 30-minute rating flowed for one minute or longer.

 

Error code: F-800

Protective Function: Excess Speed Deviation

Explanation: Speed rose to 120% of commanded value or greater, or dropped to 50% or lower.

 

Error code: F-900

Protective Function: Motor Thermal Error 1

Explanation: Motor temperature exceeded upper limit (Minor Failure)

 

Error code: F-901

Protective Function: Motor Thermal Error 2

Explanation: Motor temperature over upper limit continued for four minutes or longer.

 

Error code: F-902

Protective Function: Motor Thermal Error 3

Explanation: Break in wire occurred in the motor temperature detection thermistor. (Detected at -10 degree Celcius or less)

 

Error code: F-903

Protective Function: Heat Sink Thermal Error 1

Explanation: Heat sink temperature exceeded upper limit (Minor Failure)

 

Error code: F-904

Protective Function: Heat Sink Thermal Error 2

Explanation: Heat sink temperature over upper limit continued for one minute or longer.

 

Error code: F-905

Protective Function: Heat Sink Thermal Error 3

Explanation: Break in wire occurred in the heat sink temperature detection thermistor. (Detected at -10 degree Celcius or less)

 

 

Error code: F-906

Protective Function: Control Panel Thermal Error 1

Explanation: Panel internal temperature exceeded +55 degree Celsius (Minor Failure)

 

Error code: F-907

Protective Function: Control Panel Thermal Error 2

Explanation: Panel internal temperature exceeded +60 degree Celsius

                   

Équivalents: 
CIMR-VMW2018
Tension: 230 V
Série: VS626-VM3

CENTRE DE SERVICE AUTORISÉ YASKAWA AU CANADA

CIMR-VMS2018 Yaskawa

bottom of page