Ampérage: 255 Ampères
Tension:
230 V = 255 Ampères et 100 HP
460 V = 255 Ampères et 200 HP
575 V = 255 Ampères et 250 HP
Série: SSW-07
INSPECTION GRATUITE POUR CE DÉMARREUR PROGRESSIF
SSW070255T5SZ WEG
Numéro de pièce du fabricant :
123-456-789
Manufacturer part number :
SSW070255T5SZ
SSW070255T5SZ WEG
Serial SSW-07
Error codes
Error : E03
Meaning : Phase loss or undercurrent
Error : E04
Meaning : Overtemperature on power
Error : E05
Meaning : Overload on motor
Error : E06
Meaning : External fault (DI)
Error :E10
Meaning : Function copy fault
Error :E19
Meaning : SSW short circuit
Error :E24
Meaning : Programming fault
Error :E28
Meaning : Timeout fault at telegram reception
Error :E31
Meaning : Keypad connection failure
Error :E62
Meaning : Current limitation start timeout
Error :E63
Meaning : Stall
Error :E66
Meaning : Overcurrent
Error :E67
Meaning : Inverted phase sequence
Error :E70
Meaning : Undervoltage at electronic supply
Error : E71
Meaning : By-pass contact open
Error :E72
Meaning : Overcurrent before By-pass
Error :E74
Meaning : Current imbalance
Error :E75
Meaning : Power supply frequency out of allowed range
Error :E76
Meaning : Undercurrent before closing By-pass
Error :E77
Meaning : Closed by-pass contact or shorted SCR’s